Control chart constants table.
The factors for X-bar, R, and S control charts, by subgroup size: A2, A3, d2, D3, D4, B3, B4, and c4. The standard SPC constants, in one place.
Building a control chart by hand needs the right constants for your subgroup size. This table lists the standard factors for the X-bar, R, and S charts, from subgroup size 2 to 10.
| n | A2 | A3 | d2 | D3 | D4 | B3 | B4 | c4 |
|---|---|---|---|---|---|---|---|---|
| 2 | 1.880 | 2.659 | 1.128 | 0 | 3.267 | 0 | 3.267 | 0.7979 |
| 3 | 1.023 | 1.954 | 1.693 | 0 | 2.574 | 0 | 2.568 | 0.8862 |
| 4 | 0.729 | 1.628 | 2.059 | 0 | 2.282 | 0 | 2.266 | 0.9213 |
| 5 | 0.577 | 1.427 | 2.326 | 0 | 2.114 | 0 | 2.089 | 0.9400 |
| 6 | 0.483 | 1.287 | 2.534 | 0 | 2.004 | 0.030 | 1.970 | 0.9515 |
| 7 | 0.419 | 1.182 | 2.704 | 0.076 | 1.924 | 0.118 | 1.882 | 0.9594 |
| 8 | 0.373 | 1.099 | 2.847 | 0.136 | 1.864 | 0.185 | 1.815 | 0.9650 |
| 9 | 0.337 | 1.032 | 2.970 | 0.184 | 1.816 | 0.239 | 1.761 | 0.9693 |
| 10 | 0.308 | 0.975 | 3.078 | 0.223 | 1.777 | 0.284 | 1.716 | 0.9727 |
↓ Download as CSV · open data, free to reuse (CC BY 4.0)
n = subgroup size. A2, D3, D4 are used with R-bar; A3, B3, B4 with S-bar; d2 and c4 are unbiasing constants. Values follow the standard SPC tables (Montgomery / ASTM).
How to cite it.
Conyso. (2026). Control chart constants table [Data set]. Conyso. https://conyso.com/reference-control-chart-constants.html
DOI: pending — Zenodo archival plannedBench builds X-bar, R, S, and other control charts from your data, with the constants applied for you, transparent math, no AI.
Which constant goes where.
For an X-bar & R chart: control limits for the mean are X̄ ± A2·R̄, and the range chart limits are D3·R̄ and D4·R̄. For an X-bar & S chart: use X̄ ± A3·S̄ for the mean, and B3·S̄ and B4·S̄ for the S chart.
The constants d2 and c4 unbias estimates of the standard deviation from the average range and average standard deviation respectively. Pick the row matching your subgroup size n.
Control chart constants, answered.
What is the A2 constant used for?
A2 sets the control limits on an X-bar chart from the average range: limits are X̄ ± A2 × R̄.
What are D3 and D4?
The factors for the lower and upper control limits of an R (range) chart: LCL = D3 × R̄, UCL = D4 × R̄.
Why do the constants change with subgroup size?
Because the statistical behavior of the range and standard deviation depends on how many points are in each subgroup; the constants correct for it.